How big a battery does my house need? Size it in 4 steps

How big a battery does my house need? Size it in 4 steps

Most people buy a battery by its sticker: "5 kWh". The right size comes from the other end — what you want to keep on, and for how long. You can work it out on the back of an envelope in four steps.

Step 1: List what must stay on, with watts and hours

Write down only what you really need during an outage. For each item: watts × hours = watt-hours (Wh).

Our example is an evening-and-night outage of 12 hours:

• 4 LED lights: 4 × 9 W × 4 h = 144 Wh
• Wi-Fi router: 12 W × 12 h = 144 Wh
• TV: 80 W × 3 h = 240 Wh
• Laptop: 60 W × 3 h = 180 Wh
• Fridge (label 350 kWh/year), 12 h: ≈ 480 Wh
• Two phones charged: 20 Wh
• Total: ≈ 1,210 Wh

The fridge is the odd one out: its compressor switches on and off, so don't multiply its running watts by 12. Use the energy label instead: 350 kWh a year ÷ 365 ≈ 0.96 kWh a day, so about 0.48 kWh for half a day.

Find your own watts on the label or the plug. If you're unsure, take the higher figure.

Step 2: Add the inverter's losses

Your battery stores DC; most of these appliances use AC. The inverter in between loses some energy as heat. A simple, safe allowance is to divide by 0.9:

1,210 Wh ÷ 0.9 ≈ 1,340 Wh

The inverter also uses some power just by being switched on (its "no-load" or "self-consumption" figure). It's small per hour but adds up over a night. Check your inverter's datasheet; at, say, 40 W for 12 hours that is another 480 Wh, so:

1,340 + 480 ≈ 1,820 Wh ≈ 1.8 kWh usable

Step 3: Turn usable kWh into battery size

You can't empty a battery completely (see our post Lithium vs lead-acid batteries):

• Lithium (LiFePO4): usually run to about 80–95 % of its capacity. At 90 %: 1.8 ÷ 0.9 ≈ 2.0 kWh of battery.
• Lead-acid: usually stopped at about 50 %. 1.8 ÷ 0.5 ≈ 3.6 kWh of battery — nearly double.

Step 4: Add a cushion

Batteries lose capacity as they age, outages run long, and someone always boils water on the backup. Add a margin — about 20 % is a sensible start:

• Lithium: 2.0 × 1.2 ≈ 2.4 kWh
• Lead-acid: 3.6 × 1.2 ≈ 4.4 kWh

So this home needs about a 2.4 kWh lithium battery for a 12-hour night — for example a 48 V, 50Ah battery (48 × 50 = 2,400 Wh). If you want room for longer outages or later solar, a common 5 kWh wall battery (51.2 V × 100Ah ≈ 5.1 kWh) gives you about two such nights.

What should NOT be on the battery

Anything that makes heat: kettle, stove, oven, heaters, the hot water source, irons and hair dryers. A 2,000 W kettle running for 5 minutes uses about 167 Wh — more than the four lights in our example use in 4 hours (144 Wh) — and it needs a big inverter to start. Keep these on the non-essential side of the board.

12 V or 48 V?

Same power, different current: power = volts × amps.

• 2,000 W at 12 V ≈ 167 A
• 2,000 W at 48 V ≈ 42 A

Four times less current means much thinner cables and far less energy lost as heat in them. That's why battery-inverter makers recommend 12 V only for smaller systems (Victron suggests up to about 3,000 VA at 12 V and 48 V from 5,000 VA up), and why the popular hybrid inverters sold in South Africa run on a 48 V battery (40–60 V range). For a whole-house backup, think 48 V. 12 V suits a small power station or a router-and-lights setup.

Quick recap

1. Watts × hours for each item you need → total Wh.
2. ÷ 0.9 for the inverter, plus its no-load draw.
3. ÷ usable fraction: 0.9 lithium, 0.5 lead-acid.
4. × 1.2 cushion.

Safety line

A battery wired into your DB board or a fixed inverter is installation work: it needs a registered electrician and a Certificate of Compliance. Educational only, not design or installation advice.

Next: how many solar panels do I need to recharge that battery? (coming soon)

CIRCUIT & CURRENT

Home energy and electrical, from zero to engineer. Animated.

Explainers only — not installation advice. Electrical, solar and battery work must be done by a registered or licensed person. © Kleinson Solutions