Usually, yes. But a fridge is not like a router or a TV. It has a motor, the compressor, that switches on and off all day, and each time it starts it gulps far more power for a moment. So a fridge has to pass two tests: can the power station handle the start, and does it hold enough energy for the hours you need?
Test 1: the start-up surge (the one that trips small stations)
When the compressor kicks in, it draws roughly two to three times its running watts for a second or two. A fridge that runs at 150 W can ask for 450 W or more at the start; older or big side-by-side fridges can spike well over 1,000 W.
A power station has two output numbers on its spec sheet: rated (continuous) watts and peak or surge watts. If the surge is bigger than what the station can give, the station simply switches its output off to protect itself, and your fridge stays off.
Rule of thumb: look for a station whose rated output is comfortably above your fridge's running watts, and whose surge rating is at least three times that figure. Choose a pure sine wave inverter (most good lithium power stations are): motors don't like the cheaper "modified sine" kind.
Test 2: the daily energy (how long it lasts)
Here's the good news: the compressor isn't on all the time. In a normal kitchen it runs roughly a third to half of each hour. So you don't size by running watts; you size by the energy the fridge uses in a day.
Where to find it: the energy label (on the inside wall, the back, or the box) shows kWh per year (kWh/annum).
kWh per day = kWh per year ÷ 365
Then the runtime sum from our Wi-Fi and TV article, with the same 0.85 for inverter losses:
Hours = battery size (Wh) × 0.85 ÷ (Wh per day ÷ 24)
Worked examples: Current's corner
Modern fridge-freezer, label 350 kWh/year. 350 ÷ 365 ≈ 0.96 kWh = 960 Wh a day, so about 40 Wh an hour. On a 1,000 Wh station: 1,000 × 0.85 ÷ 40 ≈ 21 hours. A four-hour power cut uses about a fifth of the battery.
Older fridge, label 900 kWh/year. 900 ÷ 365 ≈ 2.5 kWh a day, so about 103 Wh an hour. On a 500 Wh station: 500 × 0.85 ÷ 103 ≈ 4 hours. Just enough, and only if it passes Test 1.
No label? Estimate from the sticker's watts: a 150 W fridge running about 40 % of the time ≈ 60 Wh an hour. That's a rough guess; the label figure is better.
Why your real hours may be fewer
1. Heat. On a very hot day, or in a hot garage, the compressor runs much more. Plan for up to double the energy.
2. Opening the door. Every opening makes the compressor work harder. Decide what you need, open once, close quickly.
3. The inverter's own draw. The station's AC output uses a little power even when the fridge is resting between cycles.
Do you even need to run it the whole time?
Not always. A closed fridge keeps food safely cold for about four hours without power, and a full freezer for about two days (a half-full one about one day). For short power cuts, keeping the door shut may be enough. A power station earns its keep on long outages, hot days, or when you also need Wi-Fi and lights.
So what should you buy?
Work backwards from your longest outage:
Wh needed = (fridge Wh per day ÷ 24) × hours ÷ 0.85
Modern fridge (40 Wh an hour) for 4 hours: 40 × 4 ÷ 0.85 ≈ 190 Wh. Double it for a hot day ≈ 380 Wh, and check Test 1. In practice that points to a 500 Wh-plus station with a surge rating of at least three times your fridge's running watts. Want the fridge, Wi-Fi and TV together? Add the three sums.
Quick recap
• Test 1: station surge at least about 3 × the fridge's running watts; pure sine wave.
• Test 2: label kWh/year ÷ 365 = kWh/day; Hours = Wh × 0.85 ÷ (Wh per day ÷ 24).
• Hot days and door-opening shorten it; a closed fridge holds about 4 hours on its own.
Circuit & Current explains everyday electricity in plain language. This is general information. For anything wired into your DB board, use a registered electrician.
Once a system is wired into your home, your municipality or Eskom may ask you to register it. Our Solar Registration Pack shows which office applies, the papers each one asks for and 11 questions for your installer. Fillable PDF.
See the pack · R149 ▶Organisers only, not legal or insurance advice: your municipality, Eskom or your insurer decides. Made with AI assistance from public sources. Sold by SortBright, a Kleinson Solutions (Pty) Ltd store.
CIRCUIT & CURRENT
Home energy and electrical, from zero to engineer. Animated.
YouTube · Calculator · Newsletter · Privacy
Explainers only — not installation advice. Electrical, solar and battery work must be done by a registered or licensed person. © Kleinson Solutions