The app says the battery is at 100 %. The sun is out. And still the prepaid meter keeps ticking down.
It feels like the system is broken. Usually it isn't. A hybrid inverter does exactly what its settings and its wiring tell it to, and a few of those settings quietly send you to the grid. Circuit has the seven usual reasons below, roughly in the order they catch people out.
1. The battery is only set up as backup
On many hybrids the battery does not run the house at all unless you tell it to. Sunsynk's own manual says that if the timer function is not set, the batteries will only be used for backup when there is no grid. So the battery sits full all day, waiting for load-shedding, while the house runs on solar plus grid.
Check: the time-of-use ("use timer") page. If it is switched off, the battery is a UPS, not a money-saver.
2. A time slot is holding the battery at a minimum, or charging it from the grid
Time-of-use works in slots. Each slot has a battery level the inverter will not discharge below, and many inverters let you tick "grid" per slot so the grid tops the battery up during that time. If a slot says "keep 100 %" or has the grid tick on, the inverter will use grid power to keep the battery full instead of using the battery. Some brands go further: during a forced-charge period the battery will not discharge even when solar is not enough for the load.
Check: every slot's battery level and grid tick. A common pattern is a low reserve during the day and a grid tick only at night, when you want the battery topped up before the evening.
3. A small grid draw is on purpose
With zero export switched on, the inverter keeps a small amount of power flowing in from the grid so it never pushes power backwards through your meter. Sunsynk suggests setting this "zero export power" to about 20–100 W. Over a day that adds up to roughly 0.5–2.4 kWh, about the same as leaving two to ten LED bulbs on day and night. It is normal, and it protects you on a prepaid meter that does not like reverse flow.
Check: the zero export power value. If it is set high, ask your installer whether it can come down towards the low end of that range.
4. Part of the house is not on the inverter's backup side
Most SA hybrid installs split the board in two. The backup ("essential") side runs from the inverter's LOAD port: lights, Wi-Fi, TV, fridge. The rest (the hot water source, stove, oven, pool pump) sits on the grid side. Whether solar or battery may feed that grid side depends on the inverter's settings and where the current sensor is fitted; on some set-ups it simply runs on the grid. When the grid goes off, only the backup side keeps working, which is how you can tell which side a plug is on.
Check: your DB labels, or ask your installer for the single-line drawing. Big loads on the grid side will show up on the meter.
5. The current sensor (CT clamp) is in the wrong place
The inverter only knows what the house uses if its CT clamp sits on the main incoming supply, before the board. If it is fitted on the wrong cable, for example only the backup side, the inverter cannot "see" the grid-side loads and will not try to cover them, even with a full battery.
Check: the house-load figure in the app. It should roughly equal everything running, backup and grid side together. If it only shows the backup side, have the CT position checked. This is a job for your installer, not a DIY one: the clamp sits in the main board.
6. The load is bigger than the inverter
A 5 kW inverter can deliver about 5 kW, however full the battery is. Kettle, oven and the hot water source at the same time can easily pass that. What happens then differs by model and set-up: some let the grid make up the difference, others trip with an overload fault on the backup side. Either way the battery cannot help beyond the inverter's rating.
Check: your inverter's rated output on its label or datasheet, and spread big loads out over the day.
7. The meter and the app don't count the same thing
Some owners measure a couple of hundred watts on the incoming cable with a clamp meter while the app shows almost nothing coming from the grid. Part of the answer is that motors and pumps also draw "reactive" current, and a hybrid working with the grid leaves that part to the grid; one owner was told exactly that by the manufacturer. The app, a clamp meter and your prepaid meter do not all measure the same thing, so small gaps are normal. If your prepaid units themselves keep dropping fast with the battery full, go back to reasons 1–5.
Quick checklist
• Time-of-use switched on? (Otherwise the battery is backup only.)
• Battery reserve per slot sensible, grid tick only where you want it?
• Zero export power at the low end of 20–100 W?
• Which loads are on the grid side of the board?
• House-load in the app ≈ everything running? (Else: CT position.)
• Big loads under the inverter's rating?
Safety line
Changing settings on your own inverter is your call; if anything involves the board or the CT clamp, use a registered electrician. This article explains how these systems usually behave; it is not design or installation advice.
Our Solar Registration Pack is a fillable PDF that walks you through it office by office: a page each for Eskom-direct, Cape Town, Johannesburg (City Power), Tshwane and Ekurhuleni, a document checklist, 11 questions for your installer, a tracker and a ready follow-up letter.
Get the pack · R149 ▶Organisers only, not legal or insurance advice: your municipality, Eskom or your insurer decides. Made with AI assistance from public sources. Sold by SortBright, a Kleinson Solutions (Pty) Ltd store.
CIRCUIT & CURRENT
Home energy and electrical, from zero to engineer. Animated.
YouTube · Calculator · Newsletter · Privacy
Explainers only — not installation advice. Electrical, solar and battery work must be done by a registered or licensed person. © Kleinson Solutions