A hybrid inverter quote can run to a page of model numbers and a single total at the bottom. Two quotes for "a 5 kW system" can be very different systems. Here is what each line should tell you, and the questions to ask when it doesn't.
1. The inverter
What the line should show: make and model, the continuous output in kW, and the number of solar inputs (MPPTs). A model number lets you look up the datasheet yourself.
Why it matters: the kW rating is how much the inverter can run at once. It doesn't change with the battery size. If everything you want on backup adds up to more than this number, the inverter trips.
South Africa: ask whether the inverter is on your municipality's approved list, or has an NRS 097-2-1 certificate. The City of Cape Town, for example, only authorises grid-connected systems that use an inverter from its approved list.
2. The battery
What the line should show: make and model, chemistry (most home batteries now are lithium iron phosphate, LFP), and two capacity numbers: nominal and usable.
Why it matters: the usable figure is what you actually get. A battery with 10 kWh nominal and 90 % depth of discharge gives about 9 kWh. If a quote shows only one kWh number, ask which one it is.
Warranty: it should state years and either cycles or energy throughput, and how much capacity the battery must still hold at the end. Consumer guides in Australia suggest looking for a battery that still gives at least 70 % of its rated capacity at the end of the warranty.
3. The solar panels
What the line should show: number of panels × watts each = the array size in kWp, plus make, model and two warranties: the product warranty (defects) and the performance warranty (how much output is promised after 25 years).
Current's check: 10 panels × 550 W = 5,500 W = 5.5 kWp. If the quote says "5 kW system", check which number it means: panels (kWp) or inverter (kW). They are sized separately.
4. Mounting and the roof
What the line should show: the rail or bracket type for your roof (tile, IBR, flat) and who seals the roof penetrations. Ask whether roof repairs, if needed, are included.
5. DC protection and cabling
What the line should show: DC-rated isolators or breakers between the panels and the inverter, surge protection, and the cable runs. Panels in daylight are always live, so this part of the quote is safety, not an extra.
6. The DB board work
What the line should show: which circuits move to the backup side (usually lights, plugs, fridge, Wi-Fi), whether a new sub-board is fitted, and ask whether there is a bypass switch so the house can run straight from the grid if the inverter is ever off for repair.
Why it matters: the big loads (hot water source, oven, stove, pool pump) normally stay on the grid side. A quote that puts "the whole house" on backup either has a much bigger inverter or will trip.
7. Compliance: the CoC and registration
What the line should show: a Certificate of Compliance (CoC) issued by a registered electrician, and who handles the registration with your municipality or Eskom, plus any fees.
South Africa: every system wired into your DB board needs a CoC, and registration should happen before installation, even for systems that never export. A CoC on its own does not authorise the connection.
8. Commissioning and settings
What the line should show: that the installer sets the work mode (self-use, battery-first, time-of-use), the battery limits and, if you may not export, zero export, and shows you the monitoring app.
9. Workmanship warranty
What the line should show: the installer's own warranty on the work, separate from the product warranties. Guides suggest at least five years.
10. The price
What the line should show: an itemised price, what is excluded, and the deposit and payment stages. A single lump sum with no model numbers makes two quotes impossible to compare.
Red flags
• Only one kWh number for the battery, with no "usable".
• No model numbers, only "5 kW inverter, 10 kWh battery".
• No CoC or registration on the quote.
• An inverter that isn't on your municipality's list, with no NRS 097-2-1 certificate.
• "Everything on backup" with a 5 kW inverter.
Quick recap
• Inverter kW = how much at once. Battery usable kWh = how long. Panels kWp = how much sun you catch.
• Every product line needs a model number and a warranty in years.
• In South Africa: approved inverter, CoC, registration before installation.
• Still deciding on the type of system? Read inverter vs power station and how a hybrid inverter actually works.
Circuit & Current explains everyday electricity in plain language. This is general information, not design or installation advice. Electrical, solar and battery work must be done by a registered or licensed person.
Take these along: our Solar Registration Pack has 11 questions to ask your installer before you sign, plus a page per office (Eskom-direct, Cape Town, Johannesburg, Tshwane, Ekurhuleni), a document checklist and a tracker. Fillable PDF.
Get the pack · R149 ▶Organisers only, not legal or insurance advice: your municipality, Eskom or your insurer decides. Made with AI assistance from public sources. Sold by SortBright, a Kleinson Solutions (Pty) Ltd store.
CIRCUIT & CURRENT
Home energy and electrical, from zero to engineer. Animated.
YouTube · Calculator · Newsletter · Privacy
Explainers only — not installation advice. Electrical, solar and battery work must be done by a registered or licensed person. © Kleinson Solutions